I’m wiring a type 2 surge protector and want to surface mount it on the drywall here with the cables going into the drywall and then into a breakout in the panel. What kind of conduit elbow can I get to hide the wires entering the drywall that will screw onto the threads on the surge protector? Thanks
The silver ring on the threads should be threaded off of the unit. Then you put the threads through a knockout in the side of a junction box and thread the silver ring back on, securing the device to the junction box. Attach the junction box to the wall, using one of the rear knockouts to pass the conductors through the wall. You could also use a conduit elbow tap, but I'm not sure if the threads would be the right pitch.
Yep, that's the kind. Take the device to the store so you can enssure the threads are a match and then use the silver nut to position the elbow 90° to the wall. Just make sure to get the conduit and fittings you'll need to get it through the wall and into the distribution panel as well. No point in doing it halfway.
It is, but I think the protection is better from these external ones. And I’ve had equipment damaged by close lightning strikes twice in the past 6 weeks so don’t want to take any chances 😞
Haha. It’s actually not done yet, it’s still hanging there and your message is making me feel guilty.
I bought a faceplate that should go over it and planned to cut into the drywall, drill through the bottom of the panel so I can screw the surge protector to it, then use the faceplate over it. But it’s tricky finding space.
What’s a remod box, just a big electrical box in the wall with a blank faceplate and put the surge protector in it? Then just attach the wires to romex with wire nuts?
run romex from the remod box into the panel, attach SPD to cover, wire to romex. SPD will be sticking out from the wall with this. This is why they make buss mounted SPDs btw. Way less to install. Its also one of those things, if it worked, you will never know unless you have advanced education and monitoring equipment coupled with specific knowledge of each electronic it is supposedly protecting and what "surges" would destroy them. Its borderline snake oil. Not that they are empty plastic boxes with an led, but that you will never know if it works or not. It could also fail and be sitting there protecting nothing when the next storm comes in. If you are looking to meet some warranty conditions, the buss mount or even a conditioner between the outlet and electronic may be an option also.